Release Notes: CODESYS EtherNet/IP 4.8.0.0

Key Issue Type Summary Resolution Note
EIP-954 Improvement

Improve documentation from GetAssemblyByID

Fixed
EIP-952 Bug

Logger: Duplicate logger messages in Scanner and remoteadapter

Fixed
EIP-950 Improvement

Remove outdated and redundant CHM-based Online Help from AddOn package

Fixed
EIP-946 Bug

"Demo mode expired." is shown even if licensed by 3S.dat

Fixed
EIP-943 Bug

CODESYS crash if special device is added to the scanner

Fixed
EIP-942 Improvement

IoDrvCIFXEthernetIP: Add DED. to all Device Diagnosis declarations

Fixed
EIP-924 Bug

Scanner: AcyclicState gets overwritten

Won't Fix [[GENERAL]]
it is the correct behavior that the error code “REMOTE_CALL_FAILED” is returned for a closed TCP connection
EIP-918 Improvement

CIP Object/CIP Encapsulation Layer: Add library properties for online help

Fixed
EIP-917 Bug

Scanner: Multiple Scanner with Exclusive Owner Connection are not working

Fixed
EIP-916 Bug

EDS Export: Param section is missing

Won't Fix [[GENERAL]]
The eds export uses the communication adapter eds as template and just replaces already existing sections. Sections which are missing in the template eds will not be part of the EDS after export.
The communication adapter eds of customer contains no Params section. This is why no parameters will be exported and connections have 0 OT and TO size.
Bugfix on customer side: Just add an empty [Params] section to communication adpater eds and it will work.
EIP-915 Bug

Support String parameter in EDS files

Duplicate
EIP-914 Improvement

Adapter: Close all TCP Connections if all connections are in timeout

Fixed
EIP-913 Bug

Scanner: Exception with String Assemblyparameter

Fixed
EIP-912 Improvement

Adapter: Set right configuration capability attribute value

Fixed
EIP-910 Bug

Ethernet/IP Scanner: Multicast connections do not work anymore after some time.

Fixed
EIP-909 Bug

Ethernet/IP Stack: User Parameter with 16 bit addressing does not work.

Fixed
EIP-908 Bug

Ethernet/IP Stack: Config Assembly is padded with random values.

Fixed
EIP-907 Bug

Ethernet/IP Editor: Unicode symbols are not shown correctly.

Fixed
EIP-906 Bug

Ethernet/IP Adapter: If Exclusive Owner and ListenOnly connection is configured, ListenOnly I/Os are not copied.

Fixed
EIP-904 Improvement

Adapter: Change default value of configuration capability

Duplicate
EIP-902 Bug

Adapter: Run/Idle header has wrong value

Fixed
EIP-900 Improvement

Adapter: Change datatype from config assembly

Fixed
EIP-899 Bug

Adapter: Connection establishment can cause an exception

Fixed
EIP-884 Bug

Connection is closed even TCP Keepalive is send

Won't Fix [[GENERAL]]
It is not possible to get the keep alive package from the socket to keep the tcp connection alive
EIP-856 Bug

Adapter: Enable/Disable (Reconfigure) of Module is not working.

Fixed
EIP-786 Bug

“Add” and “Delete” context menu should be disabled in “EtherNet/IP Adapter Assemblies” page during online mode

Fixed
EIP-778 Improvement

Support enumerations for I/Os

Fixed
EIP-753 Epic

Ethernet/IP Scanner: Network Overview (Usability)

Fixed
EIP-696 Epic

EIP: Adapter: Acyclic services should allow to be implemented asynchronously

Cannot Reproduce [[GENERAL]]
Already possible.
EIP-596 Bug

GUI hangs on device scan when service task is hold on breakpoint.

Won't Fix [[GENERAL]]
Duplicates CDS-91813