Key | Issue Type | Summary | Resolution | Note |
---|---|---|---|---|
EIP-954 | Improvement | Improve documentation from GetAssemblyByID |
Fixed | |
EIP-952 | Bug | Logger: Duplicate logger messages in Scanner and remoteadapter |
Fixed | |
EIP-950 | Improvement | Remove outdated and redundant CHM-based Online Help from AddOn package |
Fixed | |
EIP-946 | Bug | "Demo mode expired." is shown even if licensed by 3S.dat |
Fixed | |
EIP-943 | Bug | CODESYS crash if special device is added to the scanner |
Fixed | |
EIP-942 | Improvement | IoDrvCIFXEthernetIP: Add DED. to all Device Diagnosis declarations |
Fixed | |
EIP-924 | Bug | Scanner: AcyclicState gets overwritten |
Won't Fix | [[GENERAL]] it is the correct behavior that the error code “REMOTE_CALL_FAILED” is returned for a closed TCP connection |
EIP-918 | Improvement | CIP Object/CIP Encapsulation Layer: Add library properties for online help |
Fixed | |
EIP-917 | Bug | Scanner: Multiple Scanner with Exclusive Owner Connection are not working |
Fixed | |
EIP-916 | Bug | EDS Export: Param section is missing |
Won't Fix | [[GENERAL]] The eds export uses the communication adapter eds as template and just replaces already existing sections. Sections which are missing in the template eds will not be part of the EDS after export. The communication adapter eds of customer contains no Params section. This is why no parameters will be exported and connections have 0 OT and TO size. Bugfix on customer side: Just add an empty [Params] section to communication adpater eds and it will work. |
EIP-915 | Bug | Support String parameter in EDS files |
Duplicate | |
EIP-914 | Improvement | Adapter: Close all TCP Connections if all connections are in timeout |
Fixed | |
EIP-913 | Bug | Scanner: Exception with String Assemblyparameter |
Fixed | |
EIP-912 | Improvement | Adapter: Set right configuration capability attribute value |
Fixed | |
EIP-910 | Bug | Ethernet/IP Scanner: Multicast connections do not work anymore after some time. |
Fixed | |
EIP-909 | Bug | Ethernet/IP Stack: User Parameter with 16 bit addressing does not work. |
Fixed | |
EIP-908 | Bug | Ethernet/IP Stack: Config Assembly is padded with random values. |
Fixed | |
EIP-907 | Bug | Ethernet/IP Editor: Unicode symbols are not shown correctly. |
Fixed | |
EIP-906 | Bug | Ethernet/IP Adapter: If Exclusive Owner and ListenOnly connection is configured, ListenOnly I/Os are not copied. |
Fixed | |
EIP-904 | Improvement | Adapter: Change default value of configuration capability |
Duplicate | |
EIP-902 | Bug | Adapter: Run/Idle header has wrong value |
Fixed | |
EIP-900 | Improvement | Adapter: Change datatype from config assembly |
Fixed | |
EIP-899 | Bug | Adapter: Connection establishment can cause an exception |
Fixed | |
EIP-884 | Bug | Connection is closed even TCP Keepalive is send |
Won't Fix | [[GENERAL]] It is not possible to get the keep alive package from the socket to keep the tcp connection alive |
EIP-856 | Bug | Adapter: Enable/Disable (Reconfigure) of Module is not working. |
Fixed | |
EIP-786 | Bug | “Add” and “Delete” context menu should be disabled in “EtherNet/IP Adapter Assemblies” page during online mode |
Fixed | |
EIP-778 | Improvement | Support enumerations for I/Os |
Fixed | |
EIP-753 | Epic | Ethernet/IP Scanner: Network Overview (Usability) |
Fixed | |
EIP-696 | Epic | EIP: Adapter: Acyclic services should allow to be implemented asynchronously |
Cannot Reproduce | [[GENERAL]] Already possible. |
EIP-596 | Bug | GUI hangs on device scan when service task is hold on breakpoint. |
Won't Fix | [[GENERAL]] Duplicates CDS-91813 |